• Help Support Hardline Crawlers :

JD2 model 32 electric hydraulic conversion

BC.YOTA

Member
Joined
Apr 23, 2013
Messages
14
Hi. Im currently converting my JD2 Model 32 to electric hydraulics using a 2hp Leeson motor. wiring it for 220v ac it draws 9.2 amps. Im a little confused on the wiring as I rarely do ac wiring. Im not sure if I need to use two wire- 2 hots and ground or 3 wire- 2 hots , neutral and a ground.
on the motor I know one hot goes to L1 and the other hot to L2 and the ground to the ground screw on the frame/chassis of the motor. the dual solenoid valve is rated for 230v and so is the remote control. I just don't know what to do with the solenoid and remote wiring. im sure I wil need a junction box. any help is appreciated.
 

Attachments

  • 20150212_150046.jpg
    20150212_150046.jpg
    74 KB · Views: 291
  • 20150228_053712.jpg
    20150228_053712.jpg
    35.1 KB · Views: 277
  • wiring_with_labels.gif
    wiring_with_labels.gif
    11.8 KB · Views: 286
  • Screenshot_2015-02-26-16-39-21.jpg
    Screenshot_2015-02-26-16-39-21.jpg
    28.6 KB · Views: 263
More pics of my components
 

Attachments

  • 20150214_143533.jpg
    20150214_143533.jpg
    37.2 KB · Views: 285
  • 20150214_143543.jpg
    20150214_143543.jpg
    47.3 KB · Views: 150
  • Screenshot_2015-02-14-17-24-05.jpg
    Screenshot_2015-02-14-17-24-05.jpg
    33.2 KB · Views: 266
  • 20150214_143518.jpg
    20150214_143518.jpg
    32.4 KB · Views: 144
Pics of dual solenoid valve
 

Attachments

  • 20150121_142304.jpg
    20150121_142304.jpg
    63.5 KB · Views: 281
  • 20150214_1440241.jpg
    20150214_1440241.jpg
    50.6 KB · Views: 291
  • 20150217_172612.jpg
    20150217_172612.jpg
    61.1 KB · Views: 283
  • 20150224_220044.jpg
    20150224_220044.jpg
    62.7 KB · Views: 150
I will do a nice writeup / build thread once its done with all my pics and info / cost. Maybe going with another 2 button controller...
 
Havent figured it out yet. This is a project i work on in my spare time when im not busting my ass in the oil patch. Not in a huge rush but want it done right without letting the smoke out of my motor. Im not sure if i got the right remote or not now or if it just needs to be modified. Im almost wishing i bought a 110v ac solenoid valve instead of the 230v one i got. I msgd the manufacturer yesterday to see if i can operate my dual solenoid valve using 110v ac or if its only operated using 200-250v ac. But of course its the wknd so im waiting on a response or someone knowledgable to chime in
 
Back