Paulie
Looking for man love
Now ive got my tank, toyota AC pump already mounted on the block, now im trying to figure out pressure switches, pressure relief valve, check valve/uploader. Now i was wondering for the people that have done this and used the listed items, where did you find your parts locally
Here is what i found on Napa the Pressure switch for compressors, but isnt it 120v?
Click
Here is what i found on summit racing. was thinking of using it but not sure if its the proper item to use. everything reads right and has what i need listed on it (being 12v, being able to thread on my fittings, stops compressor at 120psi, starts compressor back up at 90psi) Probably will go with this one
Click
Now for pressure relief valves im still looking for the right one. anyone know where i can find the same as the pic i posted below. notice it sets on the top of the "T", probably stated that wrong. also need to find the right check/uploader valve.
i found this check/uploader valve that goes into the tank, which i will be putting mine onto fittings (shown in the pic below) i know it will thread into my fittings (instead of tank). i have a 1/2" (i think), fitting that goes into the hose and threads into (what im going to be using) the check valve. Seem like its the right one?
Click
Now this is my first OBA setup and trying to do it clean/right way. Found this link on the Jeep compressors. It states the valves and switchs i will need. also have the same tank as the link that describes how to convert Fire extingusher to pressure tank. Need lots of input on mainly the switches and valves, the rest is a breeze.
AC to OBA
Converting Extingusher to Tank
Here is what i found on Napa the Pressure switch for compressors, but isnt it 120v?
Click
Here is what i found on summit racing. was thinking of using it but not sure if its the proper item to use. everything reads right and has what i need listed on it (being 12v, being able to thread on my fittings, stops compressor at 120psi, starts compressor back up at 90psi) Probably will go with this one
Click
Now for pressure relief valves im still looking for the right one. anyone know where i can find the same as the pic i posted below. notice it sets on the top of the "T", probably stated that wrong. also need to find the right check/uploader valve.
i found this check/uploader valve that goes into the tank, which i will be putting mine onto fittings (shown in the pic below) i know it will thread into my fittings (instead of tank). i have a 1/2" (i think), fitting that goes into the hose and threads into (what im going to be using) the check valve. Seem like its the right one?
Click
Now this is my first OBA setup and trying to do it clean/right way. Found this link on the Jeep compressors. It states the valves and switchs i will need. also have the same tank as the link that describes how to convert Fire extingusher to pressure tank. Need lots of input on mainly the switches and valves, the rest is a breeze.
AC to OBA
Converting Extingusher to Tank
Attachments
Last edited: